Configuring with Web Based Management
5.5 The "Layer 2" menu
SCALANCE XB-200 Web Based Management
132 Configuration Manual, 04/2015, C79000-G8976-C360-02
Total Ingress Rate kb/s
Specify the data rate for all incoming frames. If "No Change is entered, the entry in the
table remains unchanged.
Egress Rate kb/s
Specify the data rate for all outgoing frames. If "No Change is entered, the entry in the
table remains unchanged
Copy to Table
If you click the button, the settings are adopted for all ports of table 2.
Table 2 has the following columns:
Port
Shows the slot and the port to which the other information relates. This field cannot be
configured. The port is made up of the module number and the port number, for example
port 0.1 is module 0, port 1.
Limit Ingress Unicast (DLF)
Enable or disable the data rate for limiting incoming unicast frames with an unresolvable
address (Destination Lookup Failure).
Limit Ingress Broadcast
Enable or disable the data rate for limiting incoming broadcast frames.
Limit Ingress Multicast
Enable or disable the data rate for limiting incoming multicast frames.
Total Ingress Rate kb/s
Specify the data rate for all incoming frames.
Egress Rate kb/s
Specify the data rate for all outgoing frames.
Note
Rounding of the values, deviation from desired value
When you input the rate values, note that the WBM rounds to corre
ct values.
If values are configured for Total Ingress Rate and Egress Rate, the actual values in
operation can deviate slightly from the set values.
Steps in configuration
1. Enter the relevant values in the columns "Total Ingress Rate" and "Egress Rate" in the
row of the port being configured.
2. To use the limitation for the incoming frames, select the check box in the row. For
outgoing frames, the value in the "Egress Rate" column is used.
3. Click the "Set Values" button.