Configuring with Web Based Management
5.5 The "Layer 2" menu
SCALANCE XB-200 Web Based Management
138 Configuration Manual, 04/2015, C79000-G8976-C360-02
Monitor Barrier
Click this check box to enable or disable Monitor Barrier
Note
Effects of monitor barrier
If you enable this option, management of the switch via the monitor port is no longer
reachable. The follo
wing port-specific functions are changed:
DCP forwarding is turned off
LLDP is turned off
Unicast, multicast and broadcast blocking is turned on
The previous statuses of these functions are no longer restored after disabling monitor
barrier again. They are
reset to the default values and may need to be reconfigured.
You can reconfigure these functions manually even if monitor barrier is turned on. The
data traffic on the monitor port is also allowed again. If you do not require this, make sure
that only the
data traffic you want to monitor is forwarded to the interface.
If mirroring is disabled, the listed port
-specific functions are reset to the default values.
This reset takes place regardless of whether the functions were configured manually or
automatica
lly by enabling monitor barrier.
The table for the basic settings contains the following boxes:
Select
Select the row you want to delete.
Session ID
The Session ID is assigned automatically when a new entry is created. You can create
precisely one session.
Session Type
Shows the type of mirroring session.
Status
Shows whether or not mirroring is enabled.
Dest. Port
From the drop-down list, select the output port to which data will be mirrored in this
session.
Procedure
1. Click the "Create" button to create an entry in the table.
The session ID is assigned automatically.
2. Select the settings.
3. Click the "Set Values" button to save and activate the selected settings.