Configuring with Web Based Management
5.5 The "Layer 2" menu
SCALANCE XB-200 Web Based Management
152 Configuration Manual, 04/2015, C79000-G8976-C360-02
P.t.P. Type
Select the required option from the drop-down list. The selection depends on the port that
is set.
"-"
Point to point is calculated automatically. If the port is set to half duplex, a point-to-
point link is not assumed.
P.t.P.
Even with half duplex, a point-to-point link is assumed.
Shared Media
Even with a full duplex connection, a point-to-point link is not assumed.
Note
Point
-to-point connection means a direct connection between two devices. A shared
media connection is
, for example, a connection to a hub.
P.t.P.
Enable or disable P.t.P.
Steps in configuration
1. In the input cells of the table row, enter the values of the port you are configuring.
2. From the drop-down lists of the cells of the table row, select the values of the port you are
configuring.
3. Click the "Set Values" button.