Configuring with Web Based Management
5.5 The "Layer 2" menu
SCALANCE XB-200 Web Based Management
160 Configuration Manual, 04/2015, C79000-G8976-C360-02
Description of the displayed boxes
The page contains the following boxes:
VLAN ID
Select the VLAN ID in which you configure a new static MAC address. If nothing is set,
"VLAN1" is set as the basic setting.
MAC Address
Enter the MAC address here.
This table contains the following columns:
Select
Select the row you want to delete.
VLAN ID
Shows the VLAN-ID assigned to this MAC address.
MAC Address
Shows the MAC address of the node that the device has learned or the user has
configured.
Status
Shows the status of each address entry:
Static
Configured by the user. Static addresses are stored permanently; in other words, they
are not deleted when the aging time expires or when the switch is restarted.
Invalid
These values are not evaluated.
Port
Shows the port via which the node with the specified address can be reached. Frames
received by the device whose destination address matches this address will be forwarded
to this port.
Note
You can only specify one
port for unicast addresses.
Steps in configuration
To edit the entries, follow the steps below.
Creating a new entry
1. Select the relevant VLAN ID.
2. Enter the MAC address in the "MAC Address" input box.
3. Click the "Create" button to create a new entry in the table.
4. Click the "Refresh" button.
5. Select the relevant port from the drop-down list.
6. Click the "Set Values" button.