Configuring with Web Based Management
5.5 The "Layer 2" menu
SCALANCE XB-200 Web Based Management
162 Configuration Manual, 04/2015, C79000-G8976-C360-02
Description of the displayed boxes
Table 1 has the following columns:
1st column
Shows that the settings are valid for all ports of table 2.
Setting
Select the setting from the drop-down list. You have the following setting options:
enabled
Enables the port lock function.
disabled
Disables the port lock function.
No Change
Table 2 remains unchanged.
Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
Port
This column lists all the ports available on this device.
Check box "Setting"
Enable or disable access control for the port.
Steps in configuration
Enabling access control for an individual port
1. Select the check box in the relevant row in table 2.
2. To apply the changes, click the "Set Values" button.
Enabling access control for all ports
1. In the "Setting" drop-down list, select the "enabled" entry.
2. Click the "Copy to Table" button. The check box is enabled for all ports in table 2.
3. To apply the changes, click the "Set Values" button.