Configuring with Web Based Management
5.3 The "Information" menu
SCALANCE XB-200 Web Based Management
62 Configuration Manual, 04/2015, C79000-G8976-C360-02
Description of the displayed values
The table has the following columns:
Port
Shows the available ports. The port is made up of the module number and the port
number, for example port 0.1 is module 0, port 1.
Note
Display of frame statistics
In the statistics relating to frame size, note that both incoming and outgoing frames are
counted.
Frame lengths
The other columns after the port number contain the absolute numbers of frames
according to their frame length.
The following frame lengths are distinguished:
64 bytes
65 - 127 bytes
128 - 255 bytes
256 - 511 bytes
512 - 1023 bytes
1024 - max.
Note
Data traffic on blocked ports
For technical re
asons, data packets can be indicated on blocked ports.
Description of the button
"Reset Counter" button
Click "Reset Counter" to reset all counters. The counters are reset by a restart.