Configuring with Web Based Management
5.4 The "System" menu
SCALANCE XB-200 Web Based Management
70 Configuration Manual, 04/2015, C79000-G8976-C360-02
Syslog Client
Enable or disable the Syslog client. You can configure other settings in "System > Syslog
Client".
DCP Server
Specify whether or not the device can be accessed with DCP (Discovery and
Configuration Protocol):
"-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
Read/Write
With DCP, device parameters can be both read and modified.
Read-Only
With DCP, device parameters can be read but cannot be modified.
Time
Select the setting from the drop-down list. The following settings are possible:
Manual
The system time is set manually. You can configure other settings in "System >
System Time > Manual Setting".
SIMATIC Time
The system time is set using a SIMATIC time transmitter. You can configure other
settings in "System > System Time > SIMATIC Time Client".
SNTP Client
The system time is set via an SNTP server. You can configure other settings in
"System > System Time > SNTP Client".
NTP Client
The system time is set via an NTP server. You can configure other settings in "System
> System Time > NTP Client".
SNMP
Select the protocol from the drop-down list. The following settings are possible:
"-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
SNMPv3
Access to device parameters is possible only with SNMP version 3. You can configure
other settings in "System > SNMP > General".
SNMPv1/v2 Read-Only
Enable or disable write access to SNMP variables with SNMPv1/v2c.
DHCP Client
Enable or disable the DHCP client. You can configure other settings in "System > DHCP
Client".
SNMPv1 Traps
Enable or disable the sending of traps (alarm frames). You can configure other settings in
"System > SNMP > Traps".