Configuring with Web Based Management
5.4 The "System" menu
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02
83
Filename
A file name is preset here for every file type.
Note
Changing the file name
You can change the file name preset in this column. After clicking the "Set Values"
button, the changed name is stored on the device and can also be used with the
Command Line Interface.
Actions
Select the action from the drop-down list. The selection depends on the selected file type,
for example you can only save the log file.
The following actions are possible:
Save file
With this selection, you save a file on the TFTP server.
Load file
With this selection, you load a file from the TFTP server.
Steps in configuration
Loading or saving data using TFTP
1. Enter the IP address of the TFTP server in the "TFTP Server IP Address" input box.
2. Enter the TFTP server port to be used in the "TFTP Server Port" input box.
3. If applicable, enter the name of a file in which you want to save the data or take the data
from in the "Filename" input box.
4. Select the action you want to execute from the "Actions" drop-down list.
5. Click the "Set Values" button to start the selected actions.
6. If a restart is necessary, a message to this effect will be output. Click the "OK" button and
a restart will follow. If you click the "Cancel" button, there is no device restart. The
changes only take effect after a restart.
Reusing configuration data
If several devices are to receive the same configuration and the IP addresses are assigned
using DHCP, the effort for configuration can be reduced by saving and reading in the
configuration data.
Follow the steps below to reuse configuration data:
1. Save the configuration data of a configured device on your PC.
2. Load this configuration file on all other devices you want to configure in this way.
3. If individual settings are necessary for specific devices, these must be made online on the
relevant device.