EasyManuals Logo

Siemens SCALANCE XB-200 Web Based Management

Siemens SCALANCE XB-200
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #90 background imageLoading...
Page #90 background image
Configuring with Web Based Management
5.4 The "System" menu
SCALANCE XB-200 Web Based Management
90 Configuration Manual, 04/2015, C79000-G8976-C360-02
SMTP Port
Enter the port via which your SMTP server can be reached.
Factory settings: 25
This setting applies to all configured SMTP servers.
SMTP Server Address
Enter the IP address of the SMTP server.
This table contains the following columns:
Select
Enable the check box in a row to be deleted.
SMTP Server Address
Shows the SMTP server IP address.
Receiver Email Address
Enter the e-mail address to which the device sends an e-mail if a fault occurs.
Procedure
1. Enable the "SMTP Client" option.
2. Enter the IP address of a the SMTP server in the "SMTP Server Address" input box.
3. Click the "Create" button. A new entry is generated in the table.
4. In the "Receiver Email Address" input box, enter the e-mail address to which the device is
to send an e-mail if a fault occurs.
5. Click the "Set Values" button.
Note
Depending on the properties and configuration of the SMTP server, it may be necessary
to adapt the "Send
er Email Address” box for the e-mails. Check with the administrator of
the SMTP server.

Table of Contents

Other manuals for Siemens SCALANCE XB-200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XB-200 and is the answer not in the manual?

Siemens SCALANCE XB-200 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XB-200
CategorySwitch
LanguageEnglish

Related product manuals