3.3 Reset and Defaults
This section describes commands for restarting the device and for restoring the original 
configuration.
3.3.1 restart
Description
With this command, you restart the device.   
Select one of the following configuration settings:
● Device restart with the current configuration
● Device restart with the factory configuration settings.
● Device restart with the default settings of the PROFINET IO profile.
● Device restart with the default settings of the EtherNet/IP profile.
● Device restart with the default settings of the Industrial Ethernet profile.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call up the command with the following parameters:
restart [{factory | pnio | ethernetip | ie}]
The parameters have the following meaning:
Parameter Description Range of values / note
without parame‐
ters
The system restarts with the current 
configuration
● You can only restart the device with administrator privileges.
● A device should only be restarted by this CLI command or the 
corresponding buttons in the WBM and not by a poer cycle on 
the device.
factory Restores the factory settings of the 
device and restarts the device.
The factory settings depend on the 
device. 
● By resetting all the settings to the factory settings, the IP address 
and the passwords are also lost. Following this, the device can 
only be accessed via the serial interface, using the Primary 
Setup Tool or using DHCP.
● With the appropriate attachment, a previously correctly 
configured device can cause circulating frames and therefore 
the failure of the data traffic.
Configuration
3.3 Reset and Defaults
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
102 Configuration Manual, 07/2017, C79000-G8976-C361-06