Result
The description of the connected device has been specified.
3.5.3.8 no poe type
Description
With this command, you delete the description for a connected device.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no poe type
Result
The description of the corresponding device is deleted.
3.5.3.9 poe prio
Description
With this command, you specify the priority of the power supply for an interface.
Requirement
You are in the Interface configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
poe prio {low|high|critical}
Configuration
3.5 PoE
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
118 Configuration Manual, 07/2017, C79000-G8976-C361-06