EasyManuals Logo

Siemens SCALANCE XC-200 Configuration Manual

Siemens SCALANCE XC-200
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #276 background imageLoading...
Page #276 background image
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no telnet-server
Result
The Telnet server is disabled.
Further notes
You enable the Telnet server with the telnet-server command.
7.1.2.7 dcp server
Description
With this command, you configure the read and write permissions for the DCP server and
enable it.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
dcp server {read-only|read-write}
The parameters have the following meaning:
Parameter Description Range of values / note
read-only only reading is permitted on the DCP
server
-
read-write reading and writing is permitted on the
DPC server
Default: read-write
Network protocols
7.1 IPv4 protocol
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
276 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Other manuals for Siemens SCALANCE XC-200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XC-200 and is the answer not in the manual?

Siemens SCALANCE XC-200 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XC-200
CategorySwitch
LanguageEnglish

Related product manuals