EasyManuals Logo

Siemens SCALANCE XC-200 Configuration Manual

Siemens SCALANCE XC-200
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #339 background imageLoading...
Page #339 background image
The parameters have the following meaning:
Parameter Description Range of values / note
GroupName Name of the group max. 32 characters
user Keyword for the user name -
UserName Name of the user max. 32 characters
security-model Specifies which security settings are
used for sending.
v1
v2c
v3
Result
The details of the group are deleted.
Further notes
You change the details of an SNMP group with the snmp group command.
You display the created SNMP groups with the show snmp group command.
You display the created SNMP user with the show snmp user command.
7.5.2.12 snmp notify
Description
With this command, you configure the details of the SNMP notifications.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp notify <NotifyName> tag <TagName> type {Trap|Inform}
[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter Description Range of values / note
NotifyName Name of the SNMP notification max. 32 characters
tag Keyword for a target key -
TagName Name of the target key max. 32 characters
Network protocols
7.5 SNMP
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 339

Table of Contents

Other manuals for Siemens SCALANCE XC-200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XC-200 and is the answer not in the manual?

Siemens SCALANCE XC-200 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XC-200
CategorySwitch
LanguageEnglish

Related product manuals