Syntax
Call up the command with the following parameters:
sntp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter Description
+ Time zones to the west of the SNTP server time zone
- Time zones to the east of the SNTP server time zone
hh Number of hours difference
mm Number of minutes difference
Enter the time difference as follows:
with sign
without spaces
Hours and minutes both two digits (with leading zero)
Default: no time difference
Result
The time zone of the system time is configured.
Further notes
You can display the settings of this function and other information with the show sntp
statuscommand.
5.3.3.3 sntp unicast-server ipv4
Description
With this command, you configure an SNTP unicast server.
Note
To avoid time jumps, make sure that there is only one time server in the network.
Requirement
The addressing mode of the SNTP client is configured as "unicast".
You are in the SNTP configuration mode.
The command prompt is:
cli(config-sntp)#
System time
5.3 SNTP client
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
158 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Other manuals for Siemens SCALANCE XC-200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XC-200 and is the answer not in the manual?

Siemens SCALANCE XC-200 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XC-200
CategorySwitch
LanguageEnglish

Related product manuals