With this command, the clients are not enabled.
To enable the clients, use the client config command.
Note
Changing several message types or clients
With each command call, you can only select one message type and one client.
If you want to process several message types or clients, it may be more efficient to first select
the all option and then disable individual elements.
12.1.8.5 no event config
Note
The IE switch does not support all parameters, refer to the section "Features not supported
(Page 30)".
Description
With this command, you configure which of the various message types of the device will no
longer be stored or forwarded.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no event config
{cold-warmstart|linkchange|authentication-failure|
rmon-alarm|power-change|rm-state-change|standby-state-change|
faultstate-change|
stp-change|vrrp-state-change|loopd-state-change|ospf-state-
change|dot1x-port-auth-state-change|poe- state-change|fmp-state-
change|env-data-change|linkcheck-change|cli-script-file-status|all}
{logtable|syslog|email|trap|faults|all}
The parameters have the following meaning:
Parameter Description
cold-warmstart Message if there is cold or warm restart
linkchange Message when there is a status change on a physical interface
Diagnostics
12.1 Event and fault handling
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
558 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Other manuals for Siemens SCALANCE XC-200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XC-200 and is the answer not in the manual?

Siemens SCALANCE XC-200 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XC-200
CategorySwitch
LanguageEnglish

Related product manuals