cli(config)#
Syntax
Call up the command with the following parameters:
no monitor session <session-id(1-1)> destination
{interface <interface-type><interface-id>}
The parameters have the following meaning:
Parameter Description Range of values / note
session-id Number of the session 1
interface Keyword for a an interface description -
interface-type Type or speed of the interface Enter a valid interface.
interface-id Module no. and port no. of the interface
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Result
The destination for the mirroring of a port is deleted.
Further notes
You configure the destination for mirroring a port with the monitor session ...
destination command.
You end and delete a session with the no monitor session command.
You display the configuration settings with the show monitor session command.
12.5.2.7 monitor session source
Description
With this command, you configure the source for mirroring a port.
Requirement
Monitoring is enabled.
You are in the Global configuration mode.
The command prompt is:
cli(config)#
Syntax
Call up the command for the port to be monitored with the following parameter assignment:
Diagnostics
12.5 Port Mirroring
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
594 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Other manuals for Siemens SCALANCE XC-200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XC-200 and is the answer not in the manual?

Siemens SCALANCE XC-200 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XC-200
CategorySwitch
LanguageEnglish

Related product manuals