6.4.2.1 passive-listening bpdu-vlan-flood
Description
With this command you enable forwarding of BPDUs for specific VLANs; in other words to all
ports that are members of a VLAN.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
passive-listening bpdu-vlan-flood
As default the function is "enabled".
Result
BPDUs for specific VLANs.
Further notes
You disable this function with the no passive-listening bpdu-vlan-flood command.
You display the status of "passive listening" with the show passive-listening command.
6.4.2.2 no passive-listening bpdu-vlan-flood
Description
With this command you enable the flooding of BPDUs to all available ports of the device
regardless of the configured VLANs.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Network structures
6.4 Passive Listening
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
266 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Other manuals for Siemens SCALANCE XC-200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XC-200 and is the answer not in the manual?

Siemens SCALANCE XC-200 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XC-200
CategorySwitch
LanguageEnglish

Related product manuals