EasyManuals Logo

Siemens SCALANCE XC-200 Configuration Manual

Siemens SCALANCE XC-200
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #356 background imageLoading...
Page #356 background image
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
send test mail
Result
An e-mail according to the currently configured SMTP settings is sent.
Further notes
You can display the current SMTP settings with the show events smtp-server command.
7.6.2.6 smtp-port
Description
With this command, you configure an SMTP port.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
smtp-port <smtp-port(1-65535)>
The parameter has the following meaning:
Parameter Description Range of values / note
smtp-port Value for the SMTP port 1 ... 65535
Default: 25
Result
An SMTP port is configured.
Network protocols
7.6 SMTP client
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
356 Configuration Manual, 07/2017, C79000-G8976-C361-06