12.5.2.4 no monitor barrier enabled
Description
With this command, you enable the communication via the monitor port.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no monitor barrier enabled
Result
Communication via the monitor port is enabled.
Further notes
You disable the communication with the monitor barrier enabled command.
You display the configuration settings with the show monitor barrier command.
12.5.2.5 monitor session destination
Description
With this command, you configure the destination for mirroring a port.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
monitor session <session-id(1-1)> destination
{interface <interface-type><interface-id>}
Diagnostics
12.5 Port Mirroring
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
592 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Other manuals for Siemens SCALANCE XC-200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XC-200 and is the answer not in the manual?

Siemens SCALANCE XC-200 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XC-200
CategorySwitch
LanguageEnglish

Related product manuals