Requirement
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
fmp rx-power [req { <integer(0-0)> | - <integer(1-40)>}] [dem
{ <integer(0-0)> | - <integer(1-40)>}]
The parameters have the following meaning:
Parameter Description Range of values / note
req Specify the value at which you are informed of the de‐
terioration of the received power by a message of the
severity level "Warning"
0 ... -40 dBm
The default value depends on the relevant
pluggable transceiver.
If you enter the value "0", the received
power is not monitored.
dem Specify the value at which you are informed of the de‐
terioration of the received power by a message of the
severity level "Critical"
0 ... -40 dBm
The default value depends on the relevant
pluggable transceiver.
If you enter the value "0", the received
power is not monitored.
Result
The limits for monitoring the received power are defined.
Further notes
You enable this function with the fmp command.
You disable this function with the no fmp command.
You display the status of this function and other information with the and show fmp limit
commands.
You define the limit values for the power loss with the command fmp power-loss.
Diagnostics
12.2 FMP
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
572 Configuration Manual, 07/2017, C79000-G8976-C361-06