General technical data
8.3 Mechanical and climatic environmental conditions
ET 200eco PN
106 Operating Instructions, 08/2016, A5E01250250-AJ
Extended environmental conditions for outdoor use
The table below provides information about the type and scope of the tests for extended
environmental conditions for outdoor use.
Salt spray IEC 60068-2-52 Severity level 1 for products used at sea or close to the ocean:
4 cycles each with:
• 2 h with 5 % NaCl at 35 °C
• 7 days at 40 °C/93 % rel. humidity
UV resistance Chamber with glass: Sun test CPS plus Fa. Atlas
Duration: 12 weeks
• Irradiance (E): 550 W/m²
• Black standard temperature (BST): 55 °C
Condensation
changing climate
DIN EN ISO 6270-2 Condensation climate with alternating humidity and air temperature (AHT):
84 cycles each with:
• 8 h at 40 °C +3 °C with 100% relative humidity (condensation)
• 16 h at 18 °C to 28 °C with 100% relative humidity
Thermal shock test IEC 60068-2-14 Na Temperature: -40 °C/+125 °C
Duration: 500 cycles (500 h)
Hot storage IEC 60068-2-2 Bb Temperature: 100 °C
Devices for operating range of extended environmental conditions in outdoor use
The following devices can be used for extended environmental conditions in outdoor use:
8 AI 4 U/I + 4 RTD/TC 8×M12
8 AI RTD/TC 8×M12 6ES5144-6KD50-0AB0 1