IO-Link Master
11.1 IO-Link Master (6ES7148-6JA00-0AB0)
ET 200eco PN
Operating Instructions, 08/2016, A5E01250250-AJ
213
Actuator selection data (output signals 0 to 3 only)
Cable length, shielded Max. 30 m
Output voltage
• Nominal value
DC 24 V
• For signal "1"
Min. 1L+/2L+ (-0.8 V)
• At signal "1"
Max. 1.3 A
• For "0" signal (residual current)
Max. 1.5 mA
Parallel wiring of two outputs
• To increase performance
No
• For redundant control of a load
Supported
Controlling of a digital input
• With resistive load
Max. 100 Hz
• With inductive load
Max. 0.5 Hz
• With lamp load
Max. 1 Hz
Limiting of the inductive shutdown voltage to
Typ. 1L+/2L+ (-47 V)
Short-circuit protection of the output
• Response threshold
Typ. 1.8 A (per channel)