IO-Link Master
11.2 IO-Link Master (6ES7148-6JD00-0AB0)
ET 200eco PN
220 Operating Instructions, 08/2016, A5E01250250-AJ
Insulation test voltage
• Ethernet interface
1500 V
rms
(IEEE802.3)
• All other circuit elements
707 V DC (type test)
• Electrical isolation / between the load voltag-
es
Yes
• between load voltage and all other circuit
elements
No
• Between Ethernet and electronic components
Yes
Status, interrupts, diagnostics
Interrupts Yes
• Hardware interrupt (device notification)
Yes
• Group error/maintenance
Yes; red/yellow LED "SF/MT"
• Bus monitoring PROFINET IO
Red "BF" LED
• Monitoring of supply voltage 1L+
Green "ON" LED
• Monitoring of supply voltage 2L+
Green "24 V DC" LED
• Existing connection to network
Green "P1 LK" and "P2 LK" LED for PROFINET
IO infeed and loop-through
• IO-Link port
– Port in IO-Link mode
– Port in SIO mode
green/red LED "IO-L"
Green LED "Q"
• Diagnostic information can be read
Yes
• Missing 2L+
Yes
• Sensor supply short-circuit
Yes; device supply to ground
Number of ports that can be controlled simulta-
4, in all mounting positions
Transmission rate 4.8 kBaud (COM1), 38.4 kBaud (COM2), 230.4