Prepare and backup project
7.4 Other transfer functions
TP 270, OP 270, MP 270B (WinCC flexible)
7-16 Operating Instructions, Edition 03/2004, 6AV6691-1DD01-0AB0
Procedure - backup using standalone ProSave
1. Start ProSave on the configuration computer using the Windows Start menu.
2. Use the "General" tab register to select the required HMI device and connection type with
corresponding connection parameters.
3. Use the "Backup" tab to select the data to be saved:
– "Recipes" or
– "Passwords" or
– Complete backup
4. Select the folder in which the *.psb backup file should be saved.
5. Configure the necessary transfer channel on the HMI device.
6. Switch the HMI device to transfer mode.
7. Start the Backup process in ProSave by using the "Start Backup" button.
A status display monitors the progress of the data transfer.
Procedure - backup using WinCC flexible
1. Use "Project > Transfer > Transfer Settings" in the WinCC flexible "Select HMI devices
for transfer" dialog to select the corresponding connection type with related connection
parameters.
2. Open the "Backup Settings" dialog in WinCC flexible using the menu commands "Project
> Transfer > Backup".
3. Select the data to be saved:
– "Recipes" or
– "Passwords" or
– "Complete Backup"
4. Select the folder in which the *.psb backup file should be saved.
5. Configure the necessary transfer channel on the HMI device.
6. Switch the HMI device to transfer mode.
7. Start the backup process in WinCC flexible using the "OK" button.
A status display monitors the progress of the data transfer.
Result
When the transfer is successfully completed, a message appears. The project is copied on
the configuration computer.
Restore
In the case of a restore process, the data backup stored on the configuration computer is
reloaded into the internal Flash memory of the HMI device.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC TP 270 and is the answer not in the manual?

Siemens SIMATIC TP 270 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC TP 270
CategoryTouch Panel
LanguageEnglish

Related product manuals