Cabinet Modules
5.4 Active Line Modules including Active Interface Modules
Cabinet Modules NEMA
198 Manual, 04/2014, A5E03586450A
Table 5- 25 Technical specifications for Active Line Modules (including Active Interface Module), 500 to 690 V 3 ph. AC
- Attached to Line Connection Module on left side
- for I
N DC
(50 Hz 690 V)
- for I
H DC
(50 Hz 690 V)
- for I
N DC
(50 Hz 500 V)
- for I
H DC
(50 Hz 500 V)
- for I
N DC
(60 Hz 575 V)
- for I
H DC
(60 Hz 575 V)
kW
kW
kW
kW
HP
560
550
435
400
600
800
705
560
510
900
1100
980
780
710
1250
1400
1215
965
880
1500
- Rated current I
N DC
- Base load current I
H DC
1)
max DC
A
A
644
573
823
732
1148
1022
1422
1266
- Rated current I
N E
A
575
735
1025
1270
- auxiliary supply 24 V DC
- 500 V AC at 50 / 60 Hz
2)
- 690 V AC at 50 / 60 Hz
2)
2)
A
A
A
1.57
3 / 4.5
2.1 / 3.1
1.67
4.4 / 6.6
3.1 / 4.6
1.87
4.4 / 6.6
3.1 / 4.6
1.87
4.4 / 6.6
3.1 / 4.6
- Active Line Module
µF
7400
11100
14400
19200
3)
- at 50 Hz 500/690 V
kW
13.6
19.2
22.8
26.1
cfm
3
2500
3136
3136
3136
Sound pressure level L
pA
(1 m) at 50/60 Hz
4)
- Busbar cross-section
- Max. conductor cross-section (IEC)
- Max. conductor cross-section (NEC, CEC)
mm
2
mm
2
PE busbar
600
240
5)
- Shielded
- Unshielded
- Shielded
ft
ft
m
7400
11100
2250
7400
11100
2250
7400
11100
2250
7400
11100
2250
Degree of protection (standard model)
(standard model, IP20)
- width
- height
6)
- depth
- width
- height
6)
inch
inch
inch
mm
mm
39.4
86.6
23.6
1000
2200
55.2
86.6
23.6
1400
2200
55.2
86.6
23.6
1400
2200
55.2
86.6
23.6
1400
2200