Electrical installation
4.2 Checklist for electrical installation
Cabinet Modules NEMA
Manual, 04/2014, A5E03586450A
67
Item
Action
included/completed?
Signal connections
19 Cabinet operation by higher-level controller / control room.
The control cables must be connected in accordance with the interface assignment
and the shield applied.
To prevent interference, the control cables must be routed separately from the power
cables.
Cabling and connections must always comply with the relevant EMC guidelines.
(→ See Chapter "Electrical installation")
20 DRIVE-CLiQ cables All DRIVE-CLiQ cables must be connected correctly.
The permissible cable lengths should be carefully ob-
served.
(→ See "S120 Commissioning Manual, Rules for wiring
with DRIVE-CLiQ")
(→ See "S120 Equipment Manual for Booksize Power
Units, DRIVE-CLiQ Cabinet Gland" and "S120 Equipment
Manual for Booksize Power Units, DRIVE-CLiQ Coupling")
Options
21 G20,
CBC10 Communication
Board
The supplied CBC10 is installed in the factory in the option
slot of the Control Unit.
(→ See Chapter "Options", Section "G20, CBC10 Commu-
nication Board")
22 G33,
CBE20 Communication
Board
The supplied CBE20 is installed in the factory in the option
slot of the Control Unit.
Remove the CBE20 in a de-energized state and note
down the MAC address. Install the CBE20 into the option
slot again.
(→ See Chapter "Options", Section "G33, CBE20 Commu-
nication Board")
23 G51 to G54,
TM150 Temperature
Sensor Module
A maximum of 12 temperature sensors (PT100, PT1000,
KTY84, PTC, bimetallic NC contact) can be connected to
the TM150 Terminal Module.
(→ See Chapter "Options", Section "G51 to G54, TM150
Temperature Sensor Module")
24 K01 to K05,
safety license for 1 to 5
axes
Activating the safety licenses.
(→ See Chapter "Options", Section "K01 to K05, Safety
license for 1 to 5 axes")
25 K46,
SMC10 Sensor Module
The SMC10 Sensor Module is used for determining the
actual motor speed and the rotor position angle.
The following encoders are supported by the SMC10 Sen-
sor Module:
Resolver, 2-pin
Resolver, multi-pin
(→ See Chapter "Options", Section "K46, SMC10 Sensor
Module for determining the actual motor speed and the
rotor position angle")