EasyManuals Logo

Siemens SIPART PS2 User Manual

Siemens SIPART PS2
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
B.2.3 Connecting NCS to EMC filter module.................................................................................319
B.2.4 Commissioning of NCS ........................................................................................................320
B.2.4.1 Prerequisites / default settings .............................................................................................320
B.2.4.2 Initialization of part-turn actuators ........................................................................................321
B.2.4.3 Initializing linear actuators with a stroke range up to 14 mm (0.55 inch) .............................321
B.2.4.4 Initializing linear actuators with a stroke range > 14 mm (0.55 inch) ...................................321
B.2.5 Technical specifications NCS...............................................................................................321
B.2.6 Dimensional drawing of non-contacting sensor ...................................................................323
B.2.7 NCS sensor scope of delivery..............................................................................................323
B.2.7.1 Scope of delivery of NCS for part-turn actuators .................................................................323
B.2.7.2 Scope of delivery of NCS for linear actuators up to 14 mm (0.55 inch) . .............................324
B.2.7.3 Scope of delivery of NCS for linear actuators > 14 mm (0.55 inch) . ...................................324
B.3 External position detection system.......................................................................................325
B.3.1 Principle of operation of external position detection system ................................................325
B.3.2 Connecting the external position detection system to the EMC filter module ......................325
B.3.3 Technical specifications of the external position detection system ......................................326
B.3.4 Scope of delivery of external position detection system ......................................................326
C Pressure gauge block...............................................................................................................................329
D Sealing plug / thread adapter ...................................................................................................................331
D.1 Intended use of accessory part ............................................................................................331
D.2 Safety instructions for accessory part ..................................................................................331
D.3 Technical specifications of accessory part...........................................................................332
D.4 Dimension drawing for accessory part .................................................................................333
E Booster .....................................................................................................................................................335
E.1 Increased sound pressure level ...........................................................................................335
E.2 Booster introduction .............................................................................................................335
E.3 Operating principle of booster ..............................................................................................336
E.4 Mounting booster, without flameproof enclosure .................................................................337
E.5 Booster mounting, flameproof enclosure .............................................................................341
E.6 Booster commissioning ........................................................................................................345
E.7 RUN 3 and 4 sequence (booster) ........................................................................................347
E.8 Booster dimension drawings ................................................................................................348
E.8.1 For positioners in non-flameproof enclosure........................................................................348
E.8.2 For positioners in flameproof enclosure ...............................................................................349
E.9 Technical specifications of booster ......................................................................................349
F Positioner with remote control electronics ................................................................................................351
F.1 Introduction ..........................................................................................................................351
F.2 19" slide-in module...............................................................................................................352
F.2.1 Commissioning positioner 6DR5910-... and 19" slide-in module .........................................352
F.2.2 Connecting the positioner to the 19" slide-in module ..........................................................354
F.2.3 Connecting multiple positioners ...........................................................................................356
F.2.4 PA cable connection for bus connection ..............................................................................357
Table of contents
SIPART PS2 with PROFIBUS PA
Operating Instructions, 05/2019, A5E00127926-AC 11

Table of Contents

Other manuals for Siemens SIPART PS2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPART PS2 and is the answer not in the manual?

Siemens SIPART PS2 Specifications

General IconGeneral
Supply Pressure1.4 to 7 bar (20 to 100 psi)
Enclosure RatingIP66/NEMA 4X
Communication ProtocolsHART, PROFIBUS PA, FOUNDATION Fieldbus
Output Pressure0 to 100% of supply pressure
Hazardous Area CertificationATEX, IECEx, FM, CSA
TypeElectropneumatic
Input Signal4-20 mA
Rotation Angle30° to 90°
Operating Temperature-40°C to +80°C
MountingLinear and rotary actuators
Air ConsumptionTypically less than 0.1 kg/h