Note
Setting/resetting of a safety-related AS-i output
If a safety-related AS-i output is set and reset using the "Output cell" cell function, only the 󹪝rst
of the four fail-safe signals can be used.
You can use output function "AS‑i1..4F‑DO" to interconnect multiple outputs of a safety-related
AS-i output or auxiliary signals (AUX) and to monitor the switching status.
Another method of interconnecting the signals in the logic is demonstrated below:
$6,B),1
$6,B),1
,1
,1
6ORWB$6,B)4
$6L)',
,1
$6L)'2
4
4
$8;
$8;
)$8/7
3 5
5 4
Figure 6-29 Controlling safety-related AS‑i outputs using function element AS‑i 1..4F‑DO
Operation
6.5 Connecting to the AS-i master via AS-Interface
SIRIUS 3RK3 Modular Safety System
Equipment Manual, 07/2020, NEB926253002000/RS-AC/006 223