Appendix
A.3 I/O Connections and Wiring
FUE1010 IP65 NEMA 4X
Operating Instructions, 12/2014, A5E03086491-AC
175
Table A- 2 Input/Output Wiring (TB2) - 7ME39400AL00 and 7ME39400AL01 I/O Module (for 7ME3500 or 7ME3530 only)
Pin#
Signal
Description
Definition
Function
1
Vo1+
Meter process variables
are assigned to individual
outputs under menu
control.
0-10 Volt Analog Output
System outputs assignable and scalable
to flow related parameters. CGND is for
cable shield terminations.
4-20mA outputs also provide a fault indi-
cation by dropping to 2mA if assigned to
flow rate and under fault conditions.
2
Vo1-
Ref. Ground
3
Vo2+
0-10 Volt Analog Output
4 Vo2- Ref. Ground
5
CGND
Chassis GND
6
Io1+
4-20mA Output 1
7
Io1-
Isolated Return
8
Io2+
4-20mA Output 2
9
Io2-
Isolated Return
10
CGND
Chassis GND
11
PG1
0 -5000 Hz Frequency
output; assignable.
Frequency Output 1
5V TTL
12
PG2
GND
GND
13
PG3
Frequency Output 2
5V TTL
14
PG4
GND
GND
0-10VDC, Load 10k ohm (min)
4-20mA Load 1k ohm (max)
Note: 7ME360x only, Totalizer pulses
TB2-11 - NEG [-] Total OC (GND TB2-2 or TB2-4)
TB2-12 - NEG [-] Total TTL (GND TB2-2 or TB2-4)
TB2-13 - POS [+] Total OC (GND TB2-2 or TB2-4)
TB2-14 - POS [+] Total TTL (GND TB2-2 or TB2-4)