Scale parameters and functions
8.17 DR 17 analog output control specifications
SIWAREX WP231
110 Manual, 07/2014, A5E31238908A-02
8.17
DR 17 analog output control specifications
8.17.1
Overview
If data record DR 17 is configured as the source for the analog output (see Analog output
source (Page 94)), specifying a control output sends a corresponding output current at the
analog output.
Procedure
In data record DR 7, check that "Control by DR17" has been configured as the source for
the analog output
Check the analog output configuration (see Analog output source (Page 94))
Enter a value in data record DR 17
Transfer the data record to the scales
Table 8- 18 Assignment of data record 17
Variable
Note
Type
Length
(bytes)
Rw
Default
Min.
Max.
Modbus
registers
Data record
number
Contains no. of data record USHORT 2 r 17 - - 1600
Length Data record length information USHORT 2 r 16 - - 1601
Application Information about which application
the data record belongs to
USHORT 2 r 101 - - 1602
Version identi-
fier
Information about current data record
version
USHORT 2 r 1 1 65635 1603
Analog output
specification
(Page 111)
Value which is to be output (only
relevant if source is "External specifi-
cation", see DR 7)
FLOAT 4 rw 0 - - 1604
Reserve 1 Reserve SHORT 2 rw 0 0 - 1606
Reserve 2 Reserve USHORT 2 rw 0 0 - 1607
8.17.2
Analog output specification
The value to be entered must be between the start value (Page 94) and the end value
(Page 94) of the analog output.