Scale parameters and functions
8.25 DR 47 logbook
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02
129
8.25
DR 47 logbook
The changes in the SecureDisplay software versions are recorded in the logbook. If the
SIWAREX has established communication with the SecureDisplay, SIWAREX checks
whether the software version of the SecureDisplay has changed. Changes are recorded in
the logbook. In this manner a more recent version of the SecureDisplay can also be used
during operation requiring calibration without the calibration being violated.
The logbook entries are present in data record 47. Scrolling in the logbook is possible using
commands 881 to 883: → Command lists (Page 139). Reading of the logbook for legal trade
use is carried out using the SecureDisplay.
Table 8- 26 Assignment of data record 47
Variable
Note
Type
Length
(bytes)
Rw
Default
Min.
Max.
Modbus
registers
Data record number Contains no. of data record USHORT 2 r 46 6900
Length Data record length information USHORT 2 r 128 6901
Application Information about which appli-
cation the data record belongs
to
USHORT 2 r 101 3902
Version identifier Information about current data
record version
USHORT 2 r 1 1 65635 6903
String header for ID of
oldest logbook entry
String header UBYTE[2] 2 r 8.8 6904
ID of oldest logbook entry ID of first logbook entry CHAR[8] 8 r " 0" 1 999999
99
6905
String header for ID of most
recent logbook entry
String header UBYTE[2] 2 r 8.8 6909
ID of most recent logbook
entry
ID of last logbook entry CHAR[8] 8 r " 0" 1 999999
99
6910
String header for selected
logbook entry
String header UBYTE[2] 2 r 8.8 6914
ID of selected logbook entry ID of selected logbook entry CHAR[8] 8 r " 0" 1 999999
99
6915
String header for logbook
event
String header UBYTE[2] 2 r 4.4 6919
Logbook event Currently only logbook for
SecureDisplay SW changes,
corresponds to entry "HMI"
CHAR[4] 4 r " " 6920
String header for old SW
version
String header UBYTE[2] 2 r 10.10 6922
Old SW version Old FW version, e.g. V1.01.03 CHAR[10] 10 r " " 6923
String header for new SW
version
String header UBYTE[2] 2 r 10.10 6928
New SW version New FW version, e.g. V1.01.04 CHAR[10] 10 r " " 6929
CRC16 Checksum of logbook entry USHORT 2 r 0 6934
Reserve Reserve USHORT 2 r 0 6935