Scale parameters and functions
8.7 DR 6 limit value settings
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02
87
8.7.4
Limit value "Empty" ON
The value for the empty range is a limit value below which the weighing module registers
and returns the status "empty". The values are entered as a percentage of the measuring
range. The "Empty" limit always refers to the current gross weight in the scale.
8.7.5
Delay time for limit value "Empty" ON
If the weight reaches the specified switch value for scales status "empty", a delay time
(defined in ms) is launched. Once the delay time is over, the switch for "empty" status
changes status provided the weight still reaches the specified switch value.