Scale parameters and functions
8.19 DR 30 current process values
SIWAREX WP231
114 Manual, 07/2014, A5E31238908A-02
Variable
Note
Type
Length
(bytes)
Rw
Default
Min.
Max.
Modbus
registers
Limit value 1 Limit value 1 has responded BIT 0 r 0 - - 3004.7
Limit value 2 Limit value 2 has responded BIT 0 r 0 - - 3004.6
Min violated Set if min. is violated BIT 0 r 0 - - 3004.5
Time incorrect Time incorrect due to empty
buffer. Reset the time.
BIT 0 r 0 - - 3005.11
Trace enabled Set if trace is running BIT 0 r 0 - - 3005.10
Operator error
at digit. input
Set in event of synch. error
resulting from command at
digit. input
BIT 0 r 0 - - 3005.9
Calibrated SIWAREX is calibrated BIT 0 r 0 - - 3005.8
Service mode Service mode is enabled BIT 0 r 0 - - 3005.7
Simulation
mode
Simulation mode is enabled BIT 0 r 0 - - 3005.6
Write protec-
tion
Write-protect jumper is ena-
bled
BIT 0 r 0 - - 3005.5
Analog output
disrupted
Analog output fault BIT 0 r 0 - - 3005.4
Reserve BIT 0 r 0 - - 3005.3
Startup Restore point startup or
restore has taken place, is
deleted again after 5 seconds
BIT 0 r 0 - - 3005.2
Fault status Operating fault BIT 0 r 0 - - 3005.1
1000 Group message "Operating
error" present
BIT 2 r 0 - - 3006.16
Reserve
BIT
0
r
0
-
-
3006.15
1104 Undervoltage BIT 0 r 0 - - 3006.14
1105 Overload BIT 0 r 0 - - 3006.12
1106 Underload BIT 0 r 0 - - 3006.11
1002 RAM error BIT 0 r 0 - - 3006.10
1102 ADC error BIT 0 r 0 - - 3006.9
1005 Reserved BIT 0 r 0 - - 3006.8
1003 Checksum error data BIT 0 r 0 - - 3006.7
1107 Reserve BIT 0 r 0 - - 3006.6
1004 Checksum error program BIT 0 r 0 - - 3006.5
Reserve - BIT 0 r 0 - - 3006.4
1001 Watchdog BIT 0 r 0 - - 3006.3
Reserve - BIT 0 r 0 - - 3006.2
Reserve - BIT 0 r 0 - - 3006.1
2000 Group message "Technologi-
cal error" present
BIT 2 0 0 - - 3007.16
2001 Taring or zeroing timeout BIT 0 r 0 - - 3007.15
2002 Trace overloaded BIT 0 r 0 - - 3007.14
2003 Zeroing not possible BIT 0 r 0 - - 3007.13
Gross process
weight
(Page 116)
Gross weight (process value) FLOAT 4 r 0 - - 3008
Net process
weight
(Page 116)
Net weight (process value) FLOAT 4 r 0 - - 3010