Scale parameters and functions
8.7 DR 6 limit value settings
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02
85
Delay time for
limit value 1
OFF, delay
time for limit
value 2 OFF
(Page 86)
Time for delayed switch-
off of limit value 1 in ms
TIME 4 rw 0 0 maxi-
mum
number
range+
1246
Limit value 1
ON, limit
value 2 ON,
limit value 1
OFF, limit
value 2 OFF
(Page 86)
Switch-on point for limit
value 2 (% of measuring
range)
FLOAT 4 rw 0 maxi-
mum
num-
ber
range
maxi-
mum
number
range
1248
Delay time for
limit value 1
ON, delay
time for limit
value 2 ON
(Page 86)
Time for delayed switch-
on of limit value 2 in ms
TIME 4 rw 0 0 maxi-
mum
number
range+
1250
Limit value 1
ON, limit
value 2 ON,
limit value 1
OFF, limit
value 2 OFF
(Page 86)
Switch-off point for limit
value 2 (% of measuring
range)
FLOAT 4 rw 0 maxi-
mum
num-
ber
range
maxi-
mum
number
range
1252
Delay time for
limit value 1
OFF, delay
time for limit
value 2 OFF
(Page 86)
Time for delayed switch-
off of limit value 2 in ms
TIME 4 rw 0 0 maxi-
mum
number
range+
1254
Limit value
"Empty" ON
(Page 87)
Limit value "empty" ON
(always based on gross
value) (% of measuring
range)
FLOAT 4 rw 0 maxi-
mum
num-
ber
range
maxi-
mum
number
range
1256
Delay time for
limit value
"Empty" ON
(Page 87)
Time for delayed switch-
on of "Empty" in ms
TIME 4 rw 0 0 maxi-
mum
number
range+
1258
Reserve 2 Reserve USHORT 2 rw 0 - - 1260
Reserve 3 Reserve USHORT 2 rw 0 - - 1261
Reserve 4 Reserve FLOAT 4 rw 0 - - 1262