TC63 AT Command Set
7.7 ATDI
s
TC63_ATC_V00.490 Page 148 of 501 5/24/05
Confidential / Draft - Do not copy
7.7 ATDI Mobile originated call to ISDN number
Syntax
Command Description
TA attempts to set up an outgoing call to ISDN number. The termination character ";" is mandatory to set up voice
calls or to send *# codes for Supplementary Services. It must not be used for data and fax calls.
Parameter Description
ISDN number
String with maximum length of 20 characters. Allowed characters: +, 0-9, A, B, C.
Note
This command may be aborted generally by receiving a character during execution. Abortion is not possible
during some states of connection setup such as handshaking.
Exec Command
ATDI<n>[;]
Response(s)
If no dialtone (parameter ATX2 or ATX4):
NO DIALTONE
If busy (parameter setting ATX3 or ATX4):
BUSY
If connection cannot be set up:
NO CARRIER
All other error reasons:
+CME ERROR
If successfully connected and non-voice call (TA switches to data state):
CONNECT <text>
When TA returns to command mode after call release:
OK
If successfully connected and voice call:
OK
Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last
V.250 % % ! % % ! ! ! ! !