TC63 AT Command Set
2.4 ATQ
s
TC63_ATC_V00.490 Page 35 of 501 5/24/05
Confidential / Draft - Do not copy
2.4 ATQ Set result code presentation mode
This parameter setting determines whether or not the TA transmits any result code to the TE. Information text
transmitted in response is not affected by this setting.
Syntax
Parameter Description
[0]
(&F)
DCE transmits result code
1 Result codes are suppressed and not transmitted
Exec Command
ATQ[<n>]
Response(s)
If <n>=0:
OK
If <n>=1:
(none)
Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last
V.250 ! % % % % % % ! % !
<n>
(num)(&W)(&V)