EasyManua.ls Logo

Siemens TC63 - SAP Request Message Parameter

Siemens TC63
501 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TC63 AT Command Set
15.2 AT^SRSM
s
TC63_ATC_V00.490 Page 382 of 501 5/24/05
Confidential / Draft - Do not copy
15.2.1 SAP Request Message Parameter
The following table shows all SAP request message parameter that are used in two cases:
An URC "^SRSM" is issued by an ME acting as SAP client, then
•an AT^SRSM write command transfers its data into an ME acting as SAP server.
SAP Request Message Parameter Mapping:
AT+CMEE=2
OK
Switch on verbose error messages (use
AT+CMEE=1 with production code)
AT+CREG=1
OK
Switch on network registration URC
AT^SSET=1
OK
Switch on SIM data ready URC
AT^SCKS=1
OK
Switch on SIM status URC
AT^SM20=0
OK
Switch on immediately. Return after attempting a call
via ATD.
AT^SRSA?
OK
Does the ME support RSA and is a SAP connection
established?
AT^SRSA=2,2,3,0
^SRSA:0
OK
Initialization of RSA mode using XSAP data format.
^SRSA:2,2,0
URC indicating SAP client start without ongoing con-
nection.
ME now starts sending SAP message
CONNECTION_REQ on dedicated RSA channel.
If a SAP server has responded and offers its SIM:
^SRSA:2,2,1
URC indicating a connection with SAP server
^SCKS:0
URC indicating the loss of (local) SIM
+CREG:0
URC indicating the deregistration from network
because of loss of SIM.
^SCKS:1
URC indicating the activation of remote SIM
ME now starts reading data from the SIM
Does the new SIM require a PIN?
+CME ERROR: SIM blocked or
+CME ERROR: SIM busy
Retry if the ME returns these messages
AT+CPIN?
+CME ERROR: SIM PIN
OK
Enter PIN
AT+CPIN=1234
OK
+CREG:2
+CREG:1
URC indicating network registration.
^SSIM READY
URC indicating that SIM data is read out.
ATD491777777777777
OK
Make a call.

Table of Contents

Related product manuals