TC63 AT Command Set
3.5 ATS18
s
TC63_ATC_V00.490 Page 86 of 501 5/24/05
Confidential / Draft - Do not copy
Examples
EXAMPLE 1
EXAMPLE 2
ATS18=1
Enables the presentation of extended call release reports.
OK
ATD03012345678
Now, a mobile originated data call fails.
+CAUSE: 8:17
An extended error report is output, followed by the result code BUSY.
BUSY
The Location ID 8 stated in Section 3.4.1 points to Section 3.4.4, with 17
= "User busy".
ATS18=1
Enables the presentation of extended call release reports.
OK
ATD03012345678
Now, a mobile originated data call is set up.
CONNECT 9600/RLP
Hello,....
+++
Call ends after remote party hung up.
+CAUSE: 8:16
Normal call release is reported, followed by the result code NO CAR-
RIER.
NO CARRIER
The Location ID 8 stated in Section 3.4.1 points to Section 3.4.4, with 16
= "Normal call clearing".