SPECIFICATIONS
14
Output Voltage
Range: 100 1000 V DC
Resolution: 1 V
Accuracy: (2 of reading + 5 V)
Voltage Display
Range: 0 1000 V
Resolution: 1 V
Accuracy: (2 of reading + 2 counts)
Resistance Display
Range:
1 - 1000 M (4 Digit, Auto Ranging)
Resolution:
500VDC
1000VDC
M
M
M
0.01
1.00 - 40.00
1.00 - 80.00
0.1
35.0 - 999.9
75.0 - 999.9
Accuracy:
(3 of reading 2 counts)
at test voltage > 500V
(7 of reading 2 counts)
at test voltage 500V
HI and LO-Limit
Range: 1 1000 M
HI-Limit: 0 = OFF
Accuracy: Same as Resistance Display Accuracy.
Delay Timer
Range: 0, 0.5 999.9 sec (0 = Continuous)
Resolution: 0.1 sec
Accuracy: (0.1 + 0.05 sec)
GROUND BOND TEST MODE
Output Voltage
Range: 6 V AC, Fixed
Output Frequency
Range: 60 or 50 Hz, User Selectable
Accuracy: 0.1
Output Current
Range: 3.0 30.0 A AC
Resolution: 0.1 A
Accuracy: (2 of setting + 0.02 A)
Current Display
Range: 0.0 30.0 A AC
Resolution: 0.1 A
Accuracy: (3 of reading + 0.1 A)
HI and LO-Limit
Range: 0 510 m for 3.0 - 10.0 A
0 200 m for 10.1 - 25.0 A
0 150 m for 25.1 - 30.0 A
Resolution: 1 m
Accuracy: (2 of setting + 2 m
Dwell Timer
Range: 0, 0.5 999.9 sec (0 = Continuous)
Resolution: 0.1 sec
Accuracy: (0.1 + 0.05 sec)
Dwell Timer
Range: 0, 0.5 999.9 sec (0 = Continuous)
Resolution: 0.1 sec

Table of Contents