EasyManua.ls Logo

Slaughter 6330 - Test Execution Commands; File Editing Commands and Companion Queries

Slaughter 6330
97 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REMOTE BUS INTERFACE: RS-232
67
data must be separated with a space. All commands that end with a question mark (?) are
query commands and require an IEEE-488 read command to retrieve the data from the
device's output buffer.
Test Execution Commands
The following commands are used to control actual output voltage and current from the
instrument. Please observe all safety precautions.
Command
Description
TEST
Execute a Test
RESET
Abort a Test in Process or Reset Failures
SAO
Set Auto Offset
TEST
Starts the test sequence at the selected step loaded into memory (RAM).
RESET
Stop or abort a test. Also used to reset a latched failure condition.
SAO
Set the offset for the Ground bond test. The cables and any test fixture should be
connected before executing the command. This command will perform an actual test and
all safety precautions should be observed when using this command.
File Editing Commands and Companion Queries
The following commands are used to create or modify Test Setup Files.
Command
Description
Value
FL <file number>
FL?
File Load
file number = 1-20
SS <step number>
SS?
Step Select
step number = 1-10
SAA
Step Add ACW test
SAD
Step Add DCW test
SAI
Step Add IR test
SAG
Step Add GND test
SAR
Step Add RUN test
SAL
Step Add LLT test
FL <file number>
Load a file from non-volatile memory into random access memory RAM.
SS <step number>
Selects the active selected step to load into RAM. The step must first be selected before
any specific parameters can be edited.

Table of Contents

Other manuals for Slaughter 6330

Related product manuals