SPECIFICATIONS
KEY FEATURES & BENEFITS OF MODEL 6330
1. Tamper proof front panel controls.
This makes it possible to limit user access to the setup screens so that only authorized
personnel can change test parameters.
2. Multiple Test Memories.
The 6330 provides twenty test memories with ten steps per memory. This is beneficial
for manufacturers testing multiple products on one production line.
3. Low-current sense.
The low current sense feature monitors the minimum level of current flow, thus
ensuring that the DUT is properly connected and that the Hipot test is being
performed.
4. Simple Menu Control.
All parameters for the setups can be adjusted through a simple menu driven program.
The easy to follow setup screens ensure that the operator correctly sets up all test
parameters.
5. Electronic dwell settings.
The electronic dwell control helps keep test results consistent by ensuring that the test
duration is the same for each product tested.
6. Electronic ramping.
Electronic ramping provides a gradual and timed method to increase output voltage to
the DUT, minimizing any damage from quickly over-applying high voltage to sensitive
DUTs.
7. Front panel LCD.
A front panel LCD allows the operator to monitor the test. The display holds the
results after a test item failure so that the operator can easily review the test results.
Failure indications are clearly displayed.
8. No load setup of trip current and output voltage.
This provides the operator with an easy and safe way to set trip currents and output
voltages since parameters are set without the high voltage present.
9. Storage of test program.
The 6330 powers up with the same parameters that were used during the last test to
avoid operator set up errors.
10. Output voltage fine adjustment.
To make the 6330 usable in all types of applications, the operator can manually bring
the voltage up or down in 10 volt increments by simply pressing the up and down
arrow keys. This makes it very easy to adjust the output voltage even while the
instrument is in the dwell mode so you can analyze test results at different voltages.