Electrical Connection
NOTICE!
For a 5.0~8.0 kW inverter, please select suitable Grid and EPS ferrules from theinverter
accessory pack in accordance with the diameter of the Grid and EPS cables actually
used.
Step 3: Loosen the swivel nut of the AC connector, pull out the rubber sealing stopper.
Figure 7-18 Disassembling the AC connector
»
When the outer diameter of the Grid or EPS cable is 17.5~18.5 mm, cut the
membrane in two holes before cable threading.
Figure 7-19 Cutting the membrane inside the holes
»
When the the outer diameter of the Grid or EPS cable is 19~21 mm, cut
the membrane first, pull out the rubber tubing inside and cut off the tubing
before cable threading.
Figure 7-20 Cutting the membrane and tubing inside the holes