Check points [Logger, Expert]
In Condmaster
®
Pro, Check point is a measuring technique with its own data input form. The input
data are a short description, max. 36 characters free text, of something which should be inspected
during a measuring or maintenance round. There are no measurements to be taken or values to
record.
Like other downloaded data, the check point texts are shown on the instrument display. Normally,
this is just a reminder - you do not have to enter or confirm anything.
In connections with comments, check points become efficient maintenance tools. Whenever
something ought to be repaired, cleaned, investigated, set a comment against the check point, e.
g. Repair! Force the measuring point on the alarm list, so that you can easily initiate and follow up
the required maintenance activity.
Please note: Your checks are not limited to the machine you are monitoring. Especially in unmanned
parts of a plant, a measuring round is the opportunity to use eyes and ears to make a general
inspection. For example, you can:
use a normal measuring point and add a check point function to remind you to open the
fuse box and check for spares.
give the fuse box a measuring point number and register it as a check point.
input the fuse box as an alternative measuring system with the values 1 = OK, 2 = spares
needed (yellow alarm), 3 = who took the last one? (red alarm).
Lights OK? Water leaking? Emergency exit blocked? Use your imagination, and the instrument as
your note book.
Check points
Text from
Condmaster
®
Pro
(36 characters)
Examples:
Belt tension, fan blades
Oil level
Cavitation, dBc max 23
Start stand-by
First aid kid
Emergency exit
Fuse box
Check point
Display text
Save,
next
ENT
ENT
SET
AT30.200.04
Exhaust fan 6
fan N
CHECK 014
AT30.200.04
Check belt tens.
fan blades
Set comment