Instruction Manual
for
AS380 Series Elevator Integrated Drive Controller
159
F13——releveling speed. It refer to the speed that elevator with the non-inspection status reach
the leveling zone in the process of automatically leveling searching, as well as the
running speed of releveling. The scope range from 0.01 to 0.15 m/s .the speed of
automatic leveling searching is inspection speed.
F14—— door-closing delay 1.
When the elevator responds to landing call, the door will keep opening within the
setting time duration. The door will close when the timing end. The function valid only
without attendant
F15—— door-closing delay 2.
When the elevator parks only with the registration call, the door will keep opening
within the setting time duration. The door will close when the timing end. The function
valid only without attendant
F16—— brake delay. The time delay from running signal dispatching to band-type brake
contactor release, when startup.
F17—— Running signal release delay when in automatic status. The time delay from band-type
brake contactor release to running signal signoff, when in automatic status.
F18—— Firefighting base station. The elevator will automatically return to default floor set by
the parameter when the firefighting switch is on.
F20—— Auto homing time delay. Auto homing function deactivated when F20=0.
Auto homing function activated when F200.The parameter is the auto homing time
delay. When the elevator respond the last call or registration and no new call or
registration come after within the time delay set by F20,elevator automatically return to
the base station set by the parameter F22. the parameter is invalid in the group control
mode because that auto base station return setting and base station position are
controlled by group control system.
F21—— Leveling switch motion delay distance. The purpose of setting this parameter is to
compensate the distance deviation caused by leveling switch motion delay distance
when doing position correction. Since this distance deviation has something to do with
speed, the parameter may be adjusted a little bit higher when the elevator run at high
speed. Under current circumstance, the rated speed of the elevator shall be under 2.5m/s.
Default value is generally used since the above-mentioned deviation distance is
relatively minor.
F22—— single or duplex return to base station. The function valid only when F20 set to non-zero
F23—— Group control mode. Set each elevator to 3 when in single or duplex. Meanwhile, it is
required to use F181 to set the principle elevator and auxiliary elevators when in parallel
connection. All elevators within the group control are set 2.
F25—— mainboard input selection 1. Constant open/close setting for switch input point X0-X15
of mainboard. It is 16 bit data. The bottom bit for X0, The ceiling bit for X15. When any
point within that range is set as constant open, the corresponding bit should be set as
zero. When any point within that range is set as constant close, the corresponding bit
should be set as one. The parameter in operator is set point by pointone bit after
anotherduring the actual operation. Therefore there is no need to calculate the value.
F26—— mainboard input selection 2. Constant open/close setting for switch input point X16-X32
of mainboard. It is 16 bit data. The bottom bit for X16, the ceiling bit for X31. When