F70——Light load uplink gain .Ranges from 0% to 300%. The default value is 100%.
F71——Light load lowlink gain.Ranges from 0% to 300%. The default value is 100%.
F72——Heavy load uplink gain. Ranges from 0% to 300%. The default value is 100%.
F73——Heavy load lowlink gain. Ranges from 0% to 300%. The default value is 100%.
F74——Light load height gain. Ranges from 0 to 1024. The default value is 512.
F75——Heavy load height gain. Ranges from 0 to 1024. The default value is 512.
Note 1:
The parameter F70F75 is only valid when the F164 set as 0,3,4. Namely: the above
three parameter is only used when the weighing device DTZZ-III-DC-SC or switch of
light-load or full-load is used in elevator for startup preload compensation,
On detailed adjusting method of above three parameters, please take reference
to the section 8, 10 of chapter 8 ( the detailed introduction about adjusting method of
the elevator startup pre-load compensation function)
F115—— time limit for door-opening timeout. If the door-opening limit switch fail to work after
the ending of time set by F115 for door opening. The elevator will stop the door-opening
and turn to close the door. The default value is 15s. range from 3s30s
F116——time limit for door-closing timeout. If the door-closing limit switch fail to work after the
ending of time set by F116 for door closing. The elevator will stop the door-closing and
turn to open the door. The default value is 15s. range from 3s30s
F117——forced door closing or opening time duration. Force the door to close or open button
(hold button) the door-opening will maintain for the setting time after pressing the
button
F118—— the disable door-opening time duration, the door-opening time duration for the disable.
F120——Anti-nuisance function and instructions for threshold of judging anti-nuisance.
0: no anti-nuisance function. 1: activation of anti-nuisance function in line with the
action of light curtain: if the elevator park for three floors consecutively without the
activation of light curtain, then the mischief can be identified. All registered instruction
signal will be cleared away.
2-64: activate the anti-nuisance function based on non-empty-load switch and registered
instructions. If the non-empty-load is not activated (the load in car is little, close to
empty-load) but registered instructions are more than the value set by F120, mischief
can be identified by the system. The entire registered instruction signal will be cleared
away.
F121——activate the function of door nudging with buzzer.
0: no activation of the function, 1: activation of the function. When the function of door
nudging with buzzer activated under the circumstance of no presence of attendant, the
elevator door will be closed forcibly once the door keep opening as the result of
repetitive F117 time setting from door-opening button, ROHB function, light curtain
action and etc.
At the same time, the system will close the door forcibly while ignoring the signals from
door-opening button, ROHB function, and light curtain.
F122——Running signal release delay during inspection, the delay time from the disconnection
of band-type contactor output to the turnoff of frequency converter output.