main board through CAN. When F164 is 4, the elevator is without electronic
weighing device but mechanic weighing switch. When F164 is 5 and 6, the elevator
weighing device is other type device. The weighing signal is transmitted into analog
quantity input port through analog quantity of DC 010V.
Note 2:
When F164 is 0,2,4,,5, the over-load, full-load, light-load switch signal
is acquired through inputted switching value signal. When F164 is 1,3,6,
the over-load, full-load, light-load switch signal is calculated based on inputted
weighing signals.
Note 3:
When F164 is 0 and 3, the pre-load compensation value at startup is calculated based
on the data of weighing signal plus that of linear correction results of
F193,F194,F195 .When F164 is 4, make sure the car loading condition based on
light-load or heavy load switch signal before doing else. Then, calculate the pre-load
weighing compensation value of light-load and heavy-load based on the parameters
F193,F194,F195. When F164 is 1,2,5 and 6, use the weighing data obtained from
weighing device as the pre-loading weighing compensation value.
F165—— special control parameters for door operation. Bit 0: door operation allowed or not in
inspection. Bit1: door-opening allowed or not during the period of adjustment and
setting. Bit2: elevator standby with/without door-opening. Bit 3: door operation with
or without onboard LED operator.
F168—— elevator serial number with IC card service.
F169—— hall up/down IC card-based call. 0: down call, 1: up call.
F170—— when the in-car IC card instruction registration is on, the corresponding floor 116
require IC card-swiping selection. The corresponding bit 1 represents the need for IC
card-swiping registration. 0 represent no need for IC car-swiping.
F171—— when the in-car IC car instruction registration is on, the corresponding floor 1732
require IC card-swiping selection.
F172—— when the in-car IC car instruction registration is on, the corresponding floor 3348
require IC card-swiping selection.
F175—— creeping speed at startup. For the comfort adjustment at startup
When starting resistance of tractor is too much, the tractor will be adjusted
appropriately to the startup creeping speed. When creep speed at startup is set as 0. it
is in no use. This value should be used together with that of startup creeping duration
F186.
F180—— speed gain. Gain for the speed given peak. The range is from 0.0% to 110.0%
The default value is 1000. (Reading as 100.0%)
F181—— mutual parallel mode ( F23=3) of elevator number setting. The range is 01, the
main elevator setting is 0. The auxiliary elevator is 1.
F182—— the installation series of deceleration switch at hoistway.(Equal to the half
deceleration switch number) Setting 0 represent the deceleration switch series based
on rated speed (see table 4.1)
F183—— setting the running speed during the hositway self-study.
F186—— creeping duration at startup, for adjusting the startup comfort. It can be used together