C-2 SPARCstation 5 Service Manual—November 1996
C
* Do not assign target 1, 3, or 6 to an external device if it is automatically assigned to an internal device.
* Do not assign target 1, 3, or 6 to an external device if it is automatically assigned to an internal device.
Table C-1 SCSI Targeting—Solaris 1.x (SunOS 4.x) Operating Systems
SCSI Device SCSI Target
Internal disk, lower bay (SCSI target automatically assigned, if present) 3*
Internal disk, upper bay (SCSI target automatically assigned, if present) 1
Internal CD-ROM drive (SCSI target factory-configured) 6
External disk drives 0, 1, 2*
External tape drives 4, 5
External CD-ROM drive 6*
Table C-2 SCSI Targeting—Solaris 2.x (SunOS 5.x) Operating Systems
SCSI Device SCSI Target
Internal disk, lower bay (SCSI target automatically assigned, if present) 3*
Internal disk, upper bay (SCSI target automatically assigned, if present) 1
Internal CD-ROM drive (SCSI target factory-configured) 6
External disk drives 0, 1, 2, 4, 5, 6*
External tape drives 0, 1, 2, 4, 5, 6*
External CD-ROM drive 0, 1, 2, 4, 5, 6*