A-2 SPARCstation 5 Model 110 Service Manual • November 1996
A.2 Input Power Requirements
TABLE A-2 lists the input power requirements for the system unit.
*Maximum input current with accessory connected to accessory outlet is 6 A.
A.3 Environmental Requirements
TABLE A-3 lists the environmental requirements for both operating and non-operating
environments.
TABLE A-2 Input Power Requirements and Power Dissipation
Parameter Specification
Nominal Frequencies 50 Hz or 60 Hz nominal
Nominal Voltage Range 100-120 Vac or 200-240 Vac
(100-240 Vac Auto)
Maximum Current AC RMS* 2 A @ 100-120 Vac, 1 A @ 200-240 Vac
AC Operating Range 87-264 Vrms, 47-63 Hz
Maximum VA Rating 200 VA
Maximum Power Consumption 200 Watts
Maximum Heat Output 683 BTU/hr
TABLE A-3 Environmental Requirements
Operating Environment:
Temperature range 0 ˚C to 40 ˚C (32 ˚F to 104 ˚F) at 20%–70% Relative
Humidity (RH), noncondensing—IEC 68-2-1, 68-2-2
Humidity 5% to 95% RH, noncondensing—IEC 68-2-2, 68-2-3
Altitude range 0 to 3000 meters (0 to 9840 feet), 10 ˚C to 40 ˚C (50 ˚F to
104˚F)—IEC 68-2-40, 68-2-41
Vibration 0.25 gravity (g) peak, 5–500 Hz, 3 perpendicular axes—
IEC 68-2-6
Shock 5 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27