D-8 SPARCstation 5 Service ManualNovember 1996
D
The probe-scsi-all test sends an inquiry command to all SCSI devices on
all the SCSI host adapters installed in the system. The first identifier listed in
the display is the SCSI host adapter address in the system device tree, followed
by the SCSI device identification data.
For example:
D.1.6 module-info
This command reports back the system CPU information including: the
microprocessor name, its revision, the speed at which it is running in
megahertz, and the SBus speed in megahertz.
For example:
D.1.7 test-memory
All of the system main memory will be tested if the system diag-switch?
parameter is true. If the diag-switch? parameter is false, this test uses
the selftest-#megs parameter in NVRAM to determine how much memory
to test. The default for the selftest-#megs parameter is 1, so only
1 megabyte of memory is tested.
ok probe-scsi-all
/iommu@0,100000000/sbus@0,10001000/espdma@5,8400000/esp@5,8800000
Target 1
Unit 0 Disk CONNER CP30548 SUN0535AEBX93081QTT
Target 3
Unit 0 Disk CONNER CP30548 SUN0535AEBX93081QTT
Target 6
Unit 0 Removable Read Only device TOSHIBA CD-ROM XM-4101TA289310/16/93
ok module-info
CPU FMI,MB86904 Rev. 2.0: 70.0 Mhz
SBus (Divide By 3) : 23.3 Mhz
ok

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems SPARCstation 5 Model 110 and is the answer not in the manual?

Sun Microsystems SPARCstation 5 Model 110 Specifications

General IconGeneral
BrandSun Microsystems
ModelSPARCstation 5 Model 110
CategoryDesktop
LanguageEnglish

Related product manuals