6-10 Sun StorEdge 3000 Family Installation, Operation, and Service Manual May 2004
1. From the Main Menu, choose “view and edit Scsi channels.”
2. Select the host channel whose Primary/Secondary ID you want to edit and press
Return.
3. Choose “view and edit scsi Id.”
If host IDs have already been configured on the host channel, they will be displayed.
If no host IDs have been configured, a dialog is displayed that says “No SCSI ID
Assignment - Add Channel SCSI ID?”
4. If a host ID has already been assigned to that channel, select an ID and press
Return to view a menu for adding or deleting SCSI IDs. Then select “Add
Channel SCSI ID.” If no host ID has been assigned to the channel, choose Yes to
add an ID.
“Primary Controller” and “Secondary Controller” are displayed in a menu.
5. Select a controller from the list and press Return.
By default, channel 0 has a primary ID (PID) and no secondary ID (SID), while
channel 1 has a SID but no PID. A list of SCSI IDs is displayed.
6. Select a SCSI ID from the list and press Return.
A confirmation dialog is displayed.